JH Technology offers a wide range of signal conditioning and isolation functions in DIN Rail, NEMA 4X and Socket style mountings that convert an incoming current or voltage signal to a proportionally scaled output signal.
All units are available in both DC or AC powered versions.
 

DIN Rail Mount
These compact units measure 0.98w x 4.8d x 3.12h inches and include a removable terminal block.
 

NEMA 4X Field Mount
The same functionality
as the rail mounted units in a NEMA 4X enclosure,
plus the option of an
LED display.
 

Socket Mount         
These plug-in devices provide an economical way to condition a broad array of signal types.
 

 
Selection Guide
Single Input Source                                  DIN Rail
Mounting
4X Field
Mounting
Socket
Mounting
 
AC Current (average): 1mA to 5A span JH5600 FT5600 JH6020
AC Current (true RMS): 1mA to 5A span JH5610 FT5610 JH6020
AC Voltage (average): 50mV to 250V span JH5600 FT5600 JH6010
AC Voltage (true RMS): 50mV to 250V span JH5610 FT5610 JH6010
DC Current: 4-20mA, voltage or current out JH5030 FT5030 JH4380P
DC Current: 4-20mA, as above w/loop power JH5040 FT5040 JH4305
DC Current: 4-20mA (4-20ma output only) JH5050     - JH4300C
DC Current: +/- 5A, 1mA min. span JH5060 FT5060 JH4300
DC Current: 1 to 100mA (user rangeable) JH5080 FT5080 JH4380W
DC Voltage: +/- 250VDC, 4mV/1V min span JH5000 FT5000 JH4300
DC Voltage: 10mV to 220V (user rangeable) JH5080 FT5080 JH4380W
DC Voltage: <1V, 4mV to 1V span JH5070 FT5070     -
Frequency: 100KHz range (fixed)     -     - JH7010
Frequency: 100KHz range (user adj.)     -     - JH7580
Potentiometer: 100 to 100K Ohms JH5800 FT5800 JH4003
RTD: 100 Ohm and others JH54xx FT54xx JH4001
Thermocouple: E, J, K, T, R, S, B or N JH5200 FT5200 JH4130
Strain Gauge: Resistance Bridge JH5500 FT5500 JH4051
 
 
Multi-Input Signal Conditioners                
 
Adder 2-Input, DC Voltage or Current JH5110 FT5110 JH4400I
Adder 3-Input, DC Voltage or Current JH5120 FT5120 JH4401I
Adder 4-Input, DC Voltage or Current     -     - JH4402I
Subtract 2-Input, DC Voltage or Current JH5130 FT5130 JH4408I
Multiply 2-Input, DC Voltage or Current JH5140 FT5140 JH4410I
Divide 2-Input, DC Voltage or Current JH5150 FT5150 JH4420I