www.techsales-nw.com

 telephone: 503-345-9710 .

 Home | Products | Industries | Product Lines | News & Events | Contacts

Products

Instrumentation > Signal Conditioners > JH Technology >




Instrumentation Products Index
 
Process & Machine
Instrumentation

Flow/Batch Controllers
Flow Computers
Process Indicators
Signal Conditioners
Oil on Water Sensors
Transmitters
Test Equipment
 
 
Search for Products by keyword(s)

 

 

 

 

 

 

JH Technology
Accessories
 
Mounting
Hardware
Power
Supplies

 


 

 

JH4305:  DC Input , Isolated Module, with Loop Supply

  • 4/20mA Input Typical, Others Available

  • Provides 24V Power to Input Loop

  • Quick-Check Red/Green Output LEDs

  • Industry Standard 8-Pin Socket Mounting

  • AC or DC Power Options

Model JH4305 provides 24Vdc loop excitation for a remote 2-wire transmitter, takes the signal from that transmitter and provides a proportional DC voltage or current output. It also may be used with DC-powered "3-wire" sensors and transmitters whose supply currents do not exceed 25mA. Input/output isolation overcomes the ground loop problems sometimes encountered with nonisolated DC-powered transmitters.

Red-green Quick-Check LEDs give a quick indication of the relative output. Red is brighter at the low end, green at high, while at mid-scale both are approximately equal. Red-only indicates offscale low while green-only indicates offscale high.

The JH4305 is a fixed-range device, precisely calibrated at the factory. AC and DC power choices are available.
 
ORDERING INFORMATION

Model Number:   Select JH4305-AC for AC power, JH4305-DC for DC power.
Input Range:   Select 4/20mA for use with 2-wire inputs, or any other range allowed by the "Input Capabilities" spec, below.
Output Range:   Specify any DC voltage or current range allowed by the "Output Capabilities" spec, below.
Power:  

Specify 115Vac, 230Vac, 12Vdc or 24Vdc.

Reverse-Acting Transmitter  
(decreasing output with increasing input): 

Specify option RT

Loop-Powered Output

4/20 mA "current sink" output stage for connection to devices whose inputs provide 24 Vdc loop excitation. Specify Option LPO.

INSTALLATION AND CONNECTIONS

These transmitters plug into any standard 8-pin circular ("octal") relay socket. JH Technology offers two sockets: DS008 for DIN-rail or surface mounting and ST008 for Snap-Track mounting.

Pin connections are:
 
    Pin 1: 
Power (AC or, if DC power option, DC plus).
    Pin 2: 
No connection.
    Pin 3: 
Power (AC or, if DC power option, DC minus).
    Pin 4: 
+24Vdc power to input transmitter (see note 1 below)
    Pin 5: 
Input plus (see note 2 below).
    Pin 6: 
Input common (see note 3 below).
    Pin 7: 
Output Signal plus (+).
    Pin 8: 
Output Signal minus (-).

Note 1: For 2-wire loop, connect to transmitter’s plus output terminal. For 3-wire transmitter, connect to transmitter’s plus power terminal
Note 2: For 2-wire loop, connect to transmitter’s minus output terminal. For 3-wire transmitter, connect to transmitter’s plus output terminal.
Note 3: Not used with 2-wire loop. For 3-wire transmitter, connect to transmitter’s minus (common) terminal.

DETAILED SPECIFICATIONS

Input Voltage Range: 50mV minimum span, +/-20V maximum input. Offset ranges are allowed. (Input Impedance: 200kohms or greater.)

Input Current Range:

1mA minimum span, +/-25mA maximum input. Specify 4/20mA when used with a 2-wire transmitter. Offset ranges are allowed. (Input Resistance: Varies with input range. Contact factory for details. 62 ohms for 4/20mA input.)

Loop Excitation
Supply:  

24Vdc regulated. 25mA max. current

Voltage Output Capabilities:  

1 volt minimum output span, -10 to +15V absolute limit. Offset ranges are allowed. Maximum output load, 10mA (1Kohm at 10V output).

Current Output Capabilities:  

1mA minimum output span, 0 to +25mA absolute limit. Positive offsets are allowed, negative outputs are not. Output drive capability, 24V (1,200 ohms max. at 20mA output).

Accuracy (factory calibration):

+/-0.1% of span

Adjustability:  

Zero and span each are adjustable approx. +/-15% of span.

Linearity:

 +/-0.05% of span or better.

Response Time:  

Under 100 milliseconds.

Isolation:  

3-way (Power/Input/Output) 1,500Vac rms (2,100V peak).

Guaranteed Operating Temperature:  

-10 to +60 deg. C (14 to 140 deg. F).

Temperature Stability:  

+/-0.02% of span per deg. C, or better.

Power Requirements:  

AC, 115 or 230Vrms, 50/60Hz, 2.5V-A. DC, 12 or 24V, 2.5W.

 