JH5140: 2 Input Multiplication (A x B)
JH5150: 2 Input Division (A / B)

  • Voltage or Current Inputs and Outputs

  • Quick-Check Red/Green Output LEDs

  • Nonstandard Ranges Available

  • DIN-Rail Mount, 1 Inch Wide

  • Unpluggable Terminal Strip

  • AC or DC Power Options

JH Technology DIN Rail Mount Signal Conditioners

JH5140/JH5150 Multiply/Divide Transmitters respond to the product or ratio of 2 DC inputs and provide a proportional, isolated DC output.

Standard calibration calculates the inputs and outputs on a percent-of-span basis. For example, in a JH5140 multiplying transmitter with 4/20mA inputs and a 0/10V output, when both inputs are at 12mA (50%) the output will be 2.5V (25%). The equation is: 0.5 x 0.5 = 0.25.

Nonstandard calibrations are available, including dissimilar input ranges and input-to-output offsets. We also can, as a special, create the function, Output = (A x B)/C. Contact us with your requirements.

Red-green Quick-Check LEDs give a quick indication of the relative output. Red is brighter at the low end, green at high, while at mid-scale both are approximately equal. Red-only indicates offscale low while green-only indicates offscale high.

Voltage or current inputs and outputs may be chosen: the input and output ranges need not be the same. Available options include AC and DC power choices and reverse-acting transmitter (decreasing output with increasing input).

ORDERING INFORMATION

Model Number:   Select from the list above according to your input function. Add suffix A (for example, JH5140A) for AC power, D for DC power
Input Range:   Specify any DC voltage or current range allowed by the "Input Capabilities" spec, below.
Output Range:  

Specify any DC voltage or current range allowed by the "Output Capabilities" spec, below.

Power:  

Specify 115Vac, 230Vac, 12Vdc or 24Vdc.

Reverse-Acting Transmitter  
(decreasing output with increasing input): 

Change the last digit of the model number to 1 (for example, JH5141A).

Loop-Powered Output

4/20mA "current sink" output stage for connection to devices whose inputs provide 24Vdc loop excitation. Change the last digit of the model number to 2 (for example, JH5142A).

Urethane Coating:  

Specify Option U.

INSTALLATION AND CONNECTIONS

JH5000 Series transmitters snap onto 35mm DIN rail. Connections are made to the front-panel terminals. The terminal strip unplugs to facilitate calibrating or replacing the transmitter.

Connections to the 8 terminals (top to bottom) are:
    1: 
Input A (Positive).
    2: 
Input Common (Negative).
    3: 
Input B (Positive).
    4: 
No connection.
    5: 
Output plus.
    6: 
Output minus.
    7: 
Power (AC or, if DC power option, DC plus).
    8: 
Power (AC or, if DC power option, DC minus).

DETAILED SPECIFICATIONS

Voltage Input Capabilities:

100mV minimum span, +/-20V maximum input. Offset ranges are allowed. (Input Impedance: 200kohms or greater.)

Input Current
Capabilities:

1mA minimum span, +/-100mA maximum input. Offset ranges are allowed.

Voltage Output Capabilities:  

1 volt minimum output span, -10 to +15V absolute limit. Offset ranges are allowed. Maximum output load, 10mA (1Kohm at 10V output).

Current Output Capabilities:  

1mA minimum output span, 0 to +25mA absolute limit. Positive offsets are allowed, negative outputs are not. Output drive capability, 24V (1,200 ohms max. at 20mA output).

Accuracy (factory calibration):

+/-0.2% of span. (For divider, input B must be greater than 20% of span to achieve rated accuracy.)

Adjustability:  

Zero and span each are adjustable approx. +/-15% of span.

Linearity:

 +/-0.05% of span or better.

Response Time:  

Under 100 milliseconds.

Isolation:  

3-way (Power/Input/Output) 1,500Vac rms (2,100V peak).

Guaranteed Operating Temperature:  

-10 to +60 deg. C (14 to 140 deg. F).

Temperature Stability:  

+/-0.02% of span per deg. C, or better.

Power Requirements:  

AC, 115 or 230Vrms, 50/60Hz, 2.5V-A. DC, 12 or 24V, 2.5W.